WCHE310 WCU310 series copper plating / copper corrosion automatic addition controller of USA The application of copper erosion can also eliminate the need for cylinder replacement and increase production capacity.
The WCU series models are economical in price. The built-in microprocessor is controlled in the form of a menu, and the copper-plated or copper-etched mode can be switched through the menu to eliminate the need to replace the controller. It can control up to 4 relays at the same time, and the output of each relay can count the total flow or operating time of the chemical pump. Users can view the difference between the copper concentration displayed in grams per liter or fluid ounces per gallon and the set point through the backlit LCD display.
Can choose the immersion sensor in the plating tank or the flow-through sensor outside the plating tank. The optical fiber photoelectric technology can provide stable, repeatable and accurate concentration measurement without being affected by the aging, color change or precipitation of the plating tank. influences. WCU series controller has self-test, calibration prompt and 4-20mA output function.
Concentration reading unit-in grams per liter (g / L) or fluid ounces per gallon (oz / gal), the backlit LCD display can continuously display the current status of set points and measured values ​​in the form of a bar graph.
Parameter adjustment-the user can adjust the concentration set point, alarm set point (high and low), blind point setting and time limit for starting the pump. The interlocking function releases the opening or closing of the output relay through external components (such as flow switch).
4 independent relay control and output terminals can be used to add copper, corrosive agent, formaldehyde or stabilizer. Each output terminal can count the total replenishment volume in units of flow or time.
The WCU series models are economical in price. The built-in microprocessor is controlled in the form of a menu, and the copper-plated or copper-etched mode can be switched through the menu to eliminate the need to replace the controller. It can control up to 4 relays at the same time, and the output of each relay can count the total flow or operating time of the chemical pump. Users can view the difference between the copper concentration displayed in grams per liter or fluid ounces per gallon and the set point through the backlit LCD display.
Can choose the immersion sensor in the plating tank or the flow-through sensor outside the plating tank. The optical fiber photoelectric technology can provide stable, repeatable and accurate concentration measurement without being affected by the aging, color change or precipitation of the plating tank. influences. WCU series controller has self-test, calibration prompt and 4-20mA output function.
Concentration reading unit-in grams per liter (g / L) or fluid ounces per gallon (oz / gal), the backlit LCD display can continuously display the current status of set points and measured values ​​in the form of a bar graph.
Parameter adjustment-the user can adjust the concentration set point, alarm set point (high and low), blind point setting and time limit for starting the pump. The interlocking function releases the opening or closing of the output relay through external components (such as flow switch).
4 independent relay control and output terminals can be used to add copper, corrosive agent, formaldehyde or stabilizer. Each output terminal can count the total replenishment volume in units of flow or time.
The American Hewei series also has:
WNI310 series (nickel-plated automatic addition controller)
WPH310 series (pH / ORP automatic addition controller)
WEC310 series (conductivity automatic addition controller)
WNI310 series (nickel-plated automatic addition controller)
WPH310 series (pH / ORP automatic addition controller)